Cat6 UTP Patch Cord (GC series)
overview
GAOXIAN Cat6 UTP exceeds all ANSI/TIA and ISO/IEC requirements. Using GAOXIAN cables is the ideal way to ensure optimal channel performance.
Describe
Patch Cord, Cable, Copper, Category 6, 4 Pair, Solid, UTP, 26 AWG, Gray & Blue
Implementation standards
Standard ANSI/TIA 568.2-D,ISO/IEC 11801-1:2017,YD/T 926.3-2009
Package
0.3m / 0.5m / 1m / 1.5m / 2m / 3m / 5m / 10m
Specifications
Product type |
Cables |
Performance level |
Category 6 |
Shield type |
UTP |
Wire |
T568B |
Nominal Jacket OD |
|
Conductor size (AWG) |
26AWG 7*8, Standard Tin Bronze |
Implementation standards |
ANSI/TIA568C.2,ISO/IEC11801-1:2008,YD/T1019-2013,YD/T926.2-2009 |
Application support |
1000BASE-T, 100BASE-T, 10BASE-T, IEEE 802.3af (Category 1 PoE), IEEE 802.3at (Category 2 PoE), IEEE 802.3bt (Category 3 PoE), IEEE 802.3bt (Category 4 PoE) |
Jacket material |
PVC plastic |
Insulation |
HDPE |
Minimum dielectric withstand voltage (contact to contact) |
1000V DC or AC peak |
Electrical resistance material |
500mΩ |
Compatibility |
Back to Cat5e |
Rated current (25℃) |
1.5A |
Power over Ethernet |
PoE and PoE+ |
Surface transmission impedance |
< 10mΩ/m(10MHz) |
Operating temperature (℃) |
-10~60℃ |
Fire protection |
UL1581, CM level, IEC 60332-1-2, GB/T 18380.12-2008 |
Plug material |
Polycarbonate |
Plug insertion cycle |
1000 |
Minimum latch holding force |
50N |
Plug compatibility |
RJ45 |
Bend radius |
50mm |
Fluke standards |
Fluke Channel Test |
Color |
Light blue and gray |
Packaging details
Standard meter package. |
0.3m / 0.5m / 1m / 1.5m / 2m / 3m / 5m / 10m |
Standard quantity |
2 pieces (0.3m); 1 piece (other); |
Stable contact fit
Whether it is a surveillance camera or a switch router, the most frightening thing is that the jumper light is not on when plugged in, which means that the link is not open and the link does not transmit signals. According to IEC standards, the RJ45 connector is plugged and pulled no less than 750 times, and the technical jumper is plugged and pulled no less than 1000 times, which is higher than the standard requirements. Gold-plated nickel-plated fork, not only firmly connected, tight contact, but also anti-oxidation and wear-resistant.
Everyone passed the test.
A link pass does not equate to the ability to transmit a signal; in other words, a link pass does not equate to the ability to pass the Fluke test; and a Fluke pass ensures that a link pass can transmit a signal. A qualified network jumper must be tested by Fluke before it leaves the factory.
gxcat6-ut-lb-gc
cables
GC SERIES