Cat6 UTP Patch Cord (GC series)

overview

GAOXIAN Cat6 UTP exceeds all ANSI/TIA and ISO/IEC requirements. Using GAOXIAN cables is the ideal way to ensure optimal channel performance.

Describe

Patch Cord, Cable, Copper, Category 6, 4 Pair, Solid, UTP, 26 AWG, Gray & Blue

Implementation standards

Standard ANSI/TIA 568.2-D,ISO/IEC 11801-1:2017,YD/T 926.3-2009

Package

0.3m / 0.5m / 1m / 1.5m / 2m / 3m / 5m / 10m

Specifications

Product type Cables
Performance level Category 6
Shield type UTP
Wire T568B
Nominal Jacket OD
Conductor size (AWG) 26AWG 7*8, Standard Tin Bronze
Implementation standards ANSI/TIA568C.2,ISO/IEC11801-1:2008,YD/T1019-2013,YD/T926.2-2009
Application support 1000BASE-T, 100BASE-T, 10BASE-T, IEEE 802.3af (Category 1 PoE), IEEE 802.3at (Category 2 PoE), IEEE 802.3bt (Category 3 PoE), IEEE 802.3bt (Category 4 PoE)
Jacket material  PVC plastic
Insulation  HDPE
Minimum dielectric withstand voltage (contact to contact)  1000V DC or AC peak
Electrical resistance material  500mΩ
Compatibility Back to Cat5e
Rated current (25℃)  1.5A
Power over Ethernet PoE and PoE+
Surface transmission impedance < 10mΩ/m(10MHz)
Operating temperature (℃) -10~60℃
Fire protection UL1581, CM level, IEC 60332-1-2, GB/T 18380.12-2008
Plug material Polycarbonate
Plug insertion cycle 1000
Minimum latch holding force 50N
Plug compatibility RJ45
Bend radius 50mm
Fluke standards Fluke Channel Test
Color Light blue and gray

Packaging details

Standard meter package. 0.3m / 0.5m / 1m / 1.5m / 2m / 3m / 5m / 10m
Standard quantity 2 pieces (0.3m); 1 piece (other);

Stable contact fit

Whether it is a surveillance camera or a switch router, the most frightening thing is that the jumper light is not on when plugged in, which means that the link is not open and the link does not transmit signals. According to IEC standards, the RJ45 connector is plugged and pulled no less than 750 times, and the technical jumper is plugged and pulled no less than 1000 times, which is higher than the standard requirements. Gold-plated nickel-plated fork, not only firmly connected, tight contact, but also anti-oxidation and wear-resistant.